Idex-health-science MCP Process – version without Settings Menu User Manual

Browse online or download User Manual for Pumps Idex-health-science MCP Process – version without Settings Menu. IDEX Health & Science MCP Process – version without Settings Menu User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MCP Process/Ismatec SA/30.07.00/CB/GP
1
English FrançaisDeutsch
Betriebsanleitung
Operating Manual
Mode d‘emploi
Pumpen-
Antrieb
Mikroprozessor-
gesteuert
Schutzgrad IP 65
ISM 915
Für Pumpenköpfe:
Pro 280 / Pro 281
Pro 380 / Pro 381
360 / 380 / 380 AD
CA 4 / CA 8 / CA 12
FMI Q0 / Q1 / Q2 / Q3
Easy-Load
Standard
Quickload
MS 3
MS/CA 4-12 / MS/CA 8-6
PTFE Membran HF/LF
PTFE Tube 2 mm / 4 mm
SB 2V / 3V / 5V
SB 2V LP
WM 5
Pump
drive
Microprocessor
controlled
Protection rating IP 65
ISM 915
For pump-heads:
Pro 280 / Pro 281
Pro 380 / Pro 381
360 / 380 / 380 AD
CA 4 / CA 8 / CA 12
FMI Q0 / Q1 / Q2 / Q3
Easy-Load
Standard
Quickload
MS 3
MS/CA 4-12 / MS/CA 8-6
PTFE Diaphragm HF/LF
PTFE Tube 2 mm / 4 mm
SB 2V / 3V / 5V
SB 2V LP
WM 5
MCP Process
Moteur de
pompe
Commandé par
microprocesseur
Classe de protection IP 65
ISM 915
Pour têtes de pompe:
Pro 280 / Pro 281
Pro 380 / Pro 381
360 / 380 / 380 AD
CA 4 / CA 8 / CA 12
FMI Q0 / Q1 / Q2 / Q3
Easy-Load
Standard
Quickload
MS 3
MS/CA 4-12 / MS/CA 8-6
PTFE Diaphragme HF/LF
PTFE Tube 2 mm / 4 mm
SB 2V / 3V / 5V
SB 2V LP
WM 5
30.07.00 CB/GP
Page view 0
1 2 3 4 5 6 ... 55 56

Summary of Contents

Page 1 - MCP Process

MCP Process/Ismatec SA/30.07.00/CB/GP1English FrançaisDeutschBetriebsanleitungOperating ManualMode d‘emploiPumpen-AntriebMikroprozessor-gesteuertSchut

Page 2

MCP Process/Ismatec SA/30.07.00/CB/GP10Operating panel1 Digital LED display2 Reduce value3 Increase value4 Run / Stop5 Calibration / Data saving6 MAX/

Page 3

MCP Process/Ismatec SA/30.07.00/CB/GP11Start-up informationAfter switching on the powersupply switch, the followingvalues are displayed:1 LED test »8.

Page 4

MCP Process/Ismatec SA/30.07.00/CB/GP12Resetting the parameters ofthe currently used programto the default values.1 Power switch »OFF«2 Push the MODE

Page 5

MCP Process/Ismatec SA/30.07.00/CB/GP13baRUNSTOPMODEmmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL Control keysa RUN/STOPStarts and s

Page 6

MCP Process/Ismatec SA/30.07.00/CB/GP14Pump-head identificationIn order to obtain correctpumping and dispensing valuesthe individual identification co

Page 7

MCP Process/Ismatec SA/30.07.00/CB/GP15Peristaltik-PumpenkopfPeristaltic pump-headTête péristaltiqueKolben-PumpenkopfPiston pump-headTête pistoniØi.d.

Page 8

MCP Process/Ismatec SA/30.07.00/CB/GP16Program selectionWhen switching the pump on, italways selects the previouslyused program.1 Change mode to PROGR

Page 9

MCP Process/Ismatec SA/30.07.00/CB/GP17Pumping by drive speed1 Change mode to PUMP rpm,1.0–240.0 rpm, adjustable insteps of 0.1 rpm2 •Enter required s

Page 10 - Affichage du mode

MCP Process/Ismatec SA/30.07.00/CB/GP18Pumping by flow rate1 Change mode toPUMP Flow rate2 Enter the required flow ratewith  keys (is displa

Page 11

MCP Process/Ismatec SA/30.07.00/CB/GP19Calibrating the flow rate1 Change mode toPUMP Flow rateEnter the required flow ratewith the  keys2 Ch

Page 12

MCP Process/Ismatec SA/30.07.00/CB/GP2ContentsSafety precautions 4–5Warranty terms 6Product 7Rear panel 8Mains voltage 8Starting the pump 9Operating p

Page 13

MCP Process/Ismatec SA/30.07.00/CB/GP20Dispensing by timeThe dispensing time can beentered from 0.1s to 999h.1 Change mode toDISP Time2 Enter the requ

Page 14

MCP Process/Ismatec SA/30.07.00/CB/GP21Dispensing by volume1 Change mode toDISP Volume2 Use the  keys for enteringthe required dispensingvol

Page 15

MCP Process/Ismatec SA/30.07.00/CB/GP22Calibrating the volume1 Change MODE toDISP Volume❖❖❖❖❖ Use the keys forentering the requireddispensin

Page 16

MCP Process/Ismatec SA/30.07.00/CB/GP23MODE1mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL CALmmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVol

Page 17

MCP Process/Ismatec SA/30.07.00/CB/GP24mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGR

Page 18

MCP Process/Ismatec SA/30.07.00/CB/GP25Intermittent dispensing (by time)Intermittent dispensing by timewith a pre-set pause time1 Go to mode PAUSE Tim

Page 19

MCP Process/Ismatec SA/30.07.00/CB/GP26mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGR

Page 20

MCP Process/Ismatec SA/30.07.00/CB/GP27Number of dispensing cyclesThe number of dispensingcycles can be entered whendispensing at intervals (by timean

Page 21

MCP Process/Ismatec SA/30.07.00/CB/GP28Drip-free dispensingWith programmable roller back-steps or piston stroke back-steps(FMI pump-head) (1–100 steps

Page 22

MCP Process/Ismatec SA/30.07.00/CB/GP29Pumping against pressureThe MCP Process can be used forcontinuous duty at a differentialpressure of max. 1.5 ba

Page 23

MCP Process/Ismatec SA/30.07.00/CB/GP3ContentsIntermittent dispensingby time 25by volume 26No. of dispensing cycles 27Drip-free dispensing 28Pumping a

Page 24

MCP Process/Ismatec SA/30.07.00/CB/GP30Overcurrent protectorThe drive MCP Processfeatures a an overload protector.When an overload conditionoccurs, it

Page 25 - (unité de temps)

MCP Process/Ismatec SA/30.07.00/CB/GP31HinweisWir verweisen auf unsereausführliche Schlauch-dokumentation.Please notePlease refer to our detailedtubin

Page 26 - (Volumen)

MCP Process/Ismatec SA/30.07.00/CB/GP32Analog interfacePin 1, GND (ground)Reference potential for all otherinputsPin 2, remoteFor changing between man

Page 27

MCP Process/Ismatec SA/30.07.00/CB/GP33Analog interfacePin 9, speed OUTThe default setting is 0–10 VDC,proportionally to the motorspeed 0–240.0 rpm.A

Page 28

MCP Process/Ismatec SA/30.07.00/CB/GP34Réglages du switch S1Exploitation par le biais de lapédale de commandeAvec le DIP switch 5, l’utilisateurpeut c

Page 29

MCP Process/Ismatec SA/30.07.00/CB/GP35Serial interfaceRS232 IN (female)A 9-pin D-socket is available onthe rear panel of the pump.Setting the pump ad

Page 30

MCP Process/Ismatec SA/30.07.00/CB/GP36Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel AntwortCo

Page 31

MCP Process/Ismatec SA/30.07.00/CB/GP37Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel AntwortCo

Page 32

MCP Process/Ismatec SA/30.07.00/CB/GP38Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel AntwortCo

Page 33

MCP Process/Ismatec SA/30.07.00/CB/GP39Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel AntwortCo

Page 34

MCP Process/Ismatec SA/30.07.00/CB/GP4Safety precautionsIsmatec® Pumps are designed forpumping applications inlaboratories and industry.As such it is

Page 35 - GND RxD TxD

MCP Process/Ismatec SA/30.07.00/CB/GP40Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel AntwortCo

Page 36

MCP Process/Ismatec SA/30.07.00/CB/GP41Jede Pumpe brauchteine eigene Adresse.(siehe Seite 35).Each pump requiresan individual address.(see page 35).Ch

Page 37

MCP Process/Ismatec SA/30.07.00/CB/GP42Logiciel de programmationLogiciel ProgEdit Créez votre programmed'application individuel. Chargez le progr

Page 38

MCP Process/Ismatec SA/30.07.00/CB/GP43AccessoiresCarte d’interface Moxa C168incluant un câble multiple avecfiches 25 pôles (mâle) pourcommander un m

Page 39

MCP Process/Ismatec SA/30.07.00/CB/GP442-Stopper-Schläuche2-stop collared tubingTubes à 2 arrêts3-Stopper-Schläuche3-stop collared tubingTubes à 3 arr

Page 40

MCP Process/Ismatec SA/30.07.00/CB/GP45MontageJedem Pumpenkopf liegt eineMontageanleitung bei.Vor Inbetriebnahme den korrektenID-Code eingeben (siehe

Page 41

MCP Process/Ismatec SA/30.07.00/CB/GP46fpoknepmuPsdaeh-pmuPepmopedetêTedoCDI *.oNDI.rN-lletseB.oNredrOednammocedoNnetarßeilFtibéD/setarwolFxam)nim/lm(

Page 42

MCP Process/Ismatec SA/30.07.00/CB/GP47epyT/pyTepyT/pyTepyT/pyTepyT/pyTepyT/pyT 3SM3SM3SM3SM3SM 6-8AC/SM6-8AC/SM6-8AC/SM6-8AC/SM6-8AC/SM 21-4AC/SM21-4

Page 43

MCP Process/Ismatec SA/30.07.00/CB/GP48epyT/pyT V2BS V3BS PL2BS 063 083 DA083 082-orP 182-orPxuanaC/slennahC23-11111nellornepmuPstellaG/srelloR66-3332

Page 44

MCP Process/Ismatec SA/30.07.00/CB/GP49HinweisBei den Angaben in den nachfol-genden Tabellen handelt es sichnur um Richtwerte, die wie folgtermittelt

Page 45

MCP Process/Ismatec SA/30.07.00/CB/GP5Safety precautions Do not manipulate the pump-head before the pump isswitched off and disconnectedfrom the mains

Page 46 - Pumpenköpfe

MCP Process/Ismatec SA/30.07.00/CB/GP50Ouverture du boîtier Afin de garantir l’étanchéitédu boîtier, il est recommandé den’ouvrir la pompe que pourre

Page 47 - Remarque

MCP Process/Ismatec SA/30.07.00/CB/GP51Opening the casing hoodSealing the casing hoodWhen the casing hood fits tight,each single screw must beremoved

Page 48 - Pumpenkanäle

MCP Process/Ismatec SA/30.07.00/CB/GP52Remplacement des fusiblesLes fusibles sont fixés sur letableau de commande (dessus) etsur le tableau réseau (de

Page 49

MCP Process/Ismatec SA/30.07.00/CB/GP53MaintenanceProvided the MCP Process isoperated properly and incompliance with this manual, thetubing is the onl

Page 50

MCP Process/Ismatec SA/30.07.00/CB/GP54 HinweisBeachten Sie ebenfalls unsereGarantie- und allgemeinen Ver-kaufs- und Lieferbedingungen.Bitte setzen S

Page 51

MCP Process/Ismatec SA/30.07.00/CB/GP55KurzanleitungDamit Sie die Bedienungsabläufeimmer griffbereit haben, finden Sienebenstehend eine Kurzanleitung

Page 52

MCP Process/Ismatec SA/30.07.00/CB/GP56Ismatec® - VertretungRepresentative/ReprésentationIsmatec® - Ihr kompetenter Ansprechpartner für anspruchsvoll

Page 53

MCP Process/Ismatec SA/30.07.00/CB/GP6Warranty termsWe warrant the perfectfunctioning of our products,provided they have been installedand operated co

Page 54

MCP Process/Ismatec SA/30.07.00/CB/GP7ProductContents of the package MCP Process driveOrder No. ISM 915incl. integrated power cord,2 m long, with IEC

Page 55 - DISP Time

MCP Process/Ismatec SA/30.07.00/CB/GP8Tableau arrière1 Interrupteur principal2 Prise d’alimentation3 RS232 IN (entrée femelle)4 RS232 OUT (sortie mâle

Page 56

MCP Process/Ismatec SA/30.07.00/CB/GP9Starting the pump Mount the pump-headaccording to the mountinginstruction manual suppliedwith the pump-head Ente

Comments to this Manuals